1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the CVVT oil control valve connector (A).
3.
Remove the installation bolt (B), and then remove the valve from the engine.
[Bank 1 / Intake]

[Bank 1 / Exhaust]

CVVT Oil Control Valve (OCV) Inspection
1. Turn the ignition switch OFF. 2. Disconnect the OCV connector. 3. Measure resistance between the OCV termina ...

CVVT Oil Control Valve (OCV) Installation
   • Install the component with the specified torques. • ...

See also:

Installation
Pressure Side Impact Sensor 1. Install the new pressure side impact sensor with the screws (B) then connect the pressure side impact sensor connector (A). ...

Defroster
CAUTION - Conductors To prevent damage to the conductors bonded to the inside surface of the rear window, never use sharp instruments or window cleaners containing abrasives to clean the window. I ...

Front Door Module  Replacement
1. Remove the front door window glass. (Refer to Front Door - "Front Door Window Glass") 2. Disconnect the front door main con ...