Kia Forte: Heated Oxygen Sensor (HO2S) Specification - Engine Control System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: Heated Oxygen Sensor (HO2S) Specification

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / Engine Control System / Heated Oxygen Sensor (HO2S) Specification

HO2S [Bank 1/Sensor 1] (Linear type)
Item
Specification
Heater Resistance (Ω)
2.4 ~ 4.0 [20°C(68°F)]

HO2S [Bank 1/Sensor 2] (Binary type)
A/F Ratio (λ)
Output Voltage(V)
RICH
0.6 ~ 1.0
LEAN
0 ~ 0.4

Item
Specification
Heater Resistance (Ω)
Approx. 9.0 [20°C(68°F)]

Heated Oxygen Sensor (HO2S) Description
Heated Oxygen Sensor (HO2S) consists of zirconium and alumina and is installed both upstream and downstream of the Catalytic Converter. It varies in accordance with the air/fuel ratio. Th ...

Heated Oxygen Sensor (HO2S) Circuit Diagram
(M/T) (A/T) ...

See also:

Components
1. Intake camshaft 2. Exhaust camshaft 3. Intake CVVT assembly 4. Exhaust CVVT assembly 5. Timing chain 6. Timing chain tensioner arm 7. Timing chain tensioner 8. T ...

Instrument Cluster Circuit Diagram
...

26 Brake Control Solenoid Valve(26/B_VFS) Specifications
Direct control VFS[26/B] ▷ Control type : Normal low type Control Pressure kpa (kgf/cm², psi) 9.81 ~ 500.14 (0.1 ~ 5.1, 1.42 ~ 72.54) Current value(mA) ...