Kia Forte: Canister Close Valve (CCV) Description

Variable Intake Solenoid (VIS) Valve Installation
Canister Close Valve (CCV) SpecificationCVVT Oil Control Valve (OCV) Description
Continuous Variable Valve Timing (CVVT) system advances or retards the
valve timing of the intake and exhaust valve in accordance with the ECM control
signal which is calculated by the engine ...
Cooling Fan Inspection
Fan Motor
1.
Disconnect the fan motor connector from the resistor.
2.
Connect the battery voltage to the "+" terminal and ...
Description
The Evaporative Emission Control System prevents fuel vapor stored in
fuel tank from vaporizing into the atmosphere. When the fuel evaporates in the
fuel tank, the vapor passes through vent h ...