Kia Forte: AGM Battery Removal - ISG (Idle Stop & Go) System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: AGM Battery Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / ISG (Idle Stop & Go) System / AGM Battery Removal

1.
Disconnect the battery terminals (A).
(1)

Tightening torque
(+) terminal :
7.8 ~ 9.8 N.m (0.8 ~ 1.0 kgf.m, 5.8 ~ 7.2 lb-ft)
(-) terminal :
4.0 ~ 6.0N.m (0.4 ~ 0.6kgf.m, 3.0 ~ 4.4lb-ft)

2.
Remove the air duct and air cleaner assembly. (Refer to Engine Mechanical System - "Air Cleaner")
3.
Remove the battery insulation pad.
4.
Remove the battery (A) after removing the mounting bracket.

Tightening torque :
8.8 ~ 13.7 N.m (0.9 ~ 1.4 kgf.m, 6.5 ~ 10.1 lb-ft)

5.
Remove the ECM.
(Refer to Engine Control/Fuel System - “Engine Control Module (ECM)”)
6.
Remove the battery tray (A) after removing the bolts.

AGM Battery Adjustment
Battery charging In general, vehicle battery charging system has three forms. 1. Constant current charge: The battery voltage gradually rises by charging w ...

AGM Battery Installation
1. Install in the reverse order of removal.    When installing the battery, ...

See also:

AGM Battery Specification
Item Specification Model type AGM 70L-DIN Capa ticy [20HR / 5HR] (AH) 70/56 Cold Cranking Amperage (A) 760 (SAE) / 610 (EN) ...

Condenser Replacement
1. Recover the refrigerant with a recovery/ recycling/ charging station. 2. Disconnect the negative (-) battery terminal. 3 ...

Cylinder Head Cover Installation
1. Install cylinder head cover. (1) The hardening sealant located on the cylinder head cover and the gap between the timing chain co ...