Kia Forte: AGM Battery Removal - ISG (Idle Stop & Go) System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: AGM Battery Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / ISG (Idle Stop & Go) System / AGM Battery Removal

1.
Disconnect the battery terminals (A).
(1)

Tightening torque
(+) terminal :
7.8 ~ 9.8 N.m (0.8 ~ 1.0 kgf.m, 5.8 ~ 7.2 lb-ft)
(-) terminal :
4.0 ~ 6.0N.m (0.4 ~ 0.6kgf.m, 3.0 ~ 4.4lb-ft)

2.
Remove the air duct and air cleaner assembly. (Refer to Engine Mechanical System - "Air Cleaner")
3.
Remove the battery insulation pad.
4.
Remove the battery (A) after removing the mounting bracket.

Tightening torque :
8.8 ~ 13.7 N.m (0.9 ~ 1.4 kgf.m, 6.5 ~ 10.1 lb-ft)

5.
Remove the ECM.
(Refer to Engine Control/Fuel System - “Engine Control Module (ECM)”)
6.
Remove the battery tray (A) after removing the bolts.

AGM Battery Adjustment
Battery charging In general, vehicle battery charging system has three forms. 1. Constant current charge: The battery voltage gradually rises by charging w ...

AGM Battery Installation
1. Install in the reverse order of removal.    When installing the battery, ...

See also:

Control Cable Inspection
1. Check the select cable for proper operation and for damage. 2. Check the shift cable for proper operation and for damage. ...

Auto Head Lamp Leveling Unit Installation
1. Install the head lamp leveling unit. 2. Reconnect the head lamp leveling unit connector. ...

Installation
   WCS(Weight Classification System) is utilizing a robust weight measuring technology. Thus, if any of the following condi ...