Kia Forte: Component Location - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Forte TD 2014-2018 Service ManualKia Forte: Component Location

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Heating,Ventilation, Air Conditioning / Air Conditioning System / Component Location

[Engine Room]

1. Receiver Drier
2. Condenser
3. Ambient Temperature Sensor
4. Compressor
5. Discharge Hose
6. Suction & Liquid Tube Assembly
7. Service Port (High Pressure)
8. Service Port (Low Pressure)
9. A/C Pressure Transducer (APT)
10. Expansion Valve

[Interior]

1. Auto Defogging Sensor
2. Photo Sensor
3. Heater & A/C Controller (Manaul)
4. Heater & A/C Controller (DATC)
5. Incar Sensor
6. Heater & Blower Unit
7. Evaporator Temperature Sensor
8. Cluster Ionizer

Refrigerant Recovery
Use only service equipment that is U.L-listed and is certified to meet the requirements of SAE J2210 to remove HFC-134a(R-134a) from the air conditioning system. ...

Compressor Oil Specification
1. The R-134a system requires synthetic compressor oil (PAG) whereas the R-12 system requires mineral compressor oil. The two oils must never be mixed. ...

See also:

Control Shaft Complete Description
Component location : Control shaft assembly is mounted on the top of the manual transaxle Function : Change the gear by shifting a shift lever. ...

Air Cleaner Removal and Installation
1. Remove the engine cover. 2. Disconnect the battery negative terminal. 3. Remove the air duct (A). ...

Adjustment
Clutch Release Cylinder Air Bleeding Procedure    • Use the specified fluid. Avoi ...