Kia Forte: Line Pressure Control Solenoid Valve Circuit Diagram - Automatic Transaxle Control System - Automatic Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: Line Pressure Control Solenoid Valve Circuit Diagram

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Line Pressure Control Solenoid Valve Circuit Diagram

Line Pressure Control Solenoid Valve Specifications
Direct control VFS[Line Pressure] ▷ Control type : Normal high type Control Pressure kpa (kgf/cm², psi) 500.14 ~ 9.81 (5.1 ~ 0.1,72.54 ~ 1.42) Current val ...

Line Pressure Control Solenoid Valve Inspection
1. Turn ignition switch OFF. 2. Disconnect the Solenoid valve connector. 3. Measure resistance between sensor ...

See also:

Inside Rear View Mirror  Replacement
[Manual Mirror]    • Put on gloves to protect your hands. ...

TPMS Receiver
1. Mode (1) Virgin State A. The receiver as a sole part is shipped in this state. ...

Front Driveshaft Component
1. Driveshaft (LH) 2. Circlip 3. Driveshaft (RH) ...