Kia Forte: 35R Clutch Control Solenoid Valve(35R/C_VFS) Specifications - Automatic Transaxle Control System - Automatic Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: 35R Clutch Control Solenoid Valve(35R/C_VFS) Specifications

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / 35R Clutch Control Solenoid Valve(35R/C_VFS) Specifications

Direct control VFS[35R/C]
▷ Control type : Normal high type
Control Pressure kpa (kgf/cm², psi)
500.14 ~ 9.81 (5.1 ~ 0.1,72.54 ~ 1.42)
Current value(mA)
50 ~ 850
 Internal resistance(Ω)
5.1

35R Clutch Control Solenoid Valve(35R/C_VFS) Description
35R Clutch (35R/C) Control Solenoid Valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the 35R clutch. ...

35R Clutch Control Solenoid Valve(35R/C_VFS) Circuit Diagram
...

See also:

Installation
   • If the oil seal on the transaxle case side is damaged and fluid is leaking, replace th ...

Diagnosis procedure by using diagnostic device
As manual for diagnosis methods by using diagnosis device, the main contents are as follows: 1. Connect self-diagnosis connector(16pins) located in the lower of driv ...

Head Lamps Component
1. Head lamp assembly lens & housing 2. Head lamp (High) lamp 3. Dust cap (High) 4. Head lamp (Low) lamp 5. Dust cap (Low) 6. Turn signal lamp socket 7. Turn signa ...

Copyright © www.kifomanual.com 2014-2025