1. |
Check that the shift lever is placed in the "N" position
|
2. |
Install the inhibitor switch (A).
|
3. |
Install the manual control lever (A).
|
4. |
Align the hole (A) in the manual control lever with the "N" position
hole (B) of the inhibitor switch and then insert the SST inhibitor switch
guide pin (09480-A3800).
|
5. |
Tighten the nut (A) and bolts (B) with the specified torque.
|
6. |
Remove the SST (09480-A3800) from the hole.
|
7. |
Connect the inhibitor switch connector (A).
|
8. |
Install the shift cable by tightening nut (B).
|
9. |
Push the shift cable to the arrow "F" to eliminate free play and
then tighten the nut (A) with the specified torque.
|
10. |
Install the battery and battery tray.
(Refer to Engine Electrical System - "Battery")
|
11. |
Install the air cleaner assembly.
(Refer to Engine Mechanical System - "Air cleaner")
|
Starter Inspection
Starter Solenoid Inspection
1.
Disconnect the lead wire from the M-terminal of solenoid switch.
2.
Connect the battery as shown. If ...
SS-B Solenoid Valve(ON/OFF) Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the Solenoid valve connector.
3.
Measure resistance between sensor ...
Accelerator Position Sensor (APS) Removal
1.
Turn the ignition switch OFF and disconnect the negative (-) battery
cable.