1. |
Turn the ignition switch ON.
|
2. |
Manually operate the control switch and measure the voltage of
the blower motor.
|
3. |
Select the control switch to raise the voltage until high speed.
Specification
* Manual Fan Speed : 3.4V ~ B+
* Auto Fan Speed : 4.5V ~ B+
|
4. |
If the measured voltage is not within specification, substitute
with a known-good power mosfet and check for proper operation.
|
5. |
Replace the power mosfet if it is proved that there is a problem
with it.
|
Ignition Coil Removal
1.
Disconnect the battery nagative terminal.
2.
Remove the engine cover.
3.
Disconnect the ignition coil connec ...
Adjustment
Clutch Release Cylinder Air Bleeding
Procedure
•
Use the specified fluid. Avoi ...
Engine Room Under Cover Removal and Installation
1.
Remove the under cover front panel (A).
2.
Remove the under covers (B).
Tightening torque:
3.9 ~ 5.9 N ...