Kia Forte: Specification - Heating,Ventilation, Air Conditioning - Kia Forte TD 2014-2018 Service ManualKia Forte: Specification

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Heating,Ventilation, Air Conditioning / Specification

Air Conditioner
Item
Specification
Compressor
Type
6VS14 (MTC) / 6VSE14 (DFATC)
Oil type & Capacity
PAG(FD46XG) 110±10cc
Pulley type
6PK-TYPE
Displacement
142cc/rev
Condenser
Heat rejection
13,008-3% kcal/hr or 13,400-3% kcal/hr
Expansion valve
Type
Block type
Refrigerant
Type
R-134a
Capacity
530±25g

Blower Unit
Item
Specification
Fresh and recirculation
Operating method
Actuator
Blower
Type
Sirocco
Speed step
Auto + 8 speed (Automatic), 1~4speed (Manual)
Speed control
Power mosfet (Automatic), Resistor (Manual)
Air filter
Type
Particle filter

Heater and Evaporator Unit
Item
Specification
Heater
Type
Pin & Tube type
Heating capacity
4,800±5% kcal/hr
Mode operating method
Actuator
Temperature operating method
Actuator
Evaporator
Temperature control type
Evaporator temperature sensor
Cooling capacity
4600±% kcal/hr
A/C ON/OFF [°C(°F)]
ON : 2.1±0.5 (35.7±32.9), OFF: 0.6±0.5 (33.0±32.9)

Heating,Ventilation, Air Conditioning
...

Tightening Torque
Part tightened N.m Kgf.m lbf.ft Condenser - Discharge hose 7.8~11.7 0.8~1.2 5.7~8.6 Condenser - Liquid tube Comp ...

See also:

ESC Control Module Removal
1. Turn the ignition switch OFF. 2. Pull up the lock of the HECU connector (A) , then disconnect the connector. ...

Side Body
* These dimensions indicated in this figure are actual-measurement dimensions. [ Unit : mm (inch) ] Front side m ...

Front Washer Motor Removal
   - When servicing the washer pump, be careful not to damage the washer pump seal. ...