Kia Forte: Compressor Installation - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Forte TD 2014-2018 Service ManualKia Forte: Compressor Installation

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Heating,Ventilation, Air Conditioning / Air Conditioning System / Compressor Installation

1.
Make sure the compressor mounting bolt with the correct length is screwed in. Tighten the mounting bolts (A) with the specified tightening order.

Tightening torque :
19.6 ~ 33.3 N.m (2.0 ~ 3.4 kgf.m, 14.5 ~ 24.6 lbf.ft)

[Gamma engine]

[Nu engine]

2.
Install in the reverse order of removal.
A.
If you install a new compressor, drain all the refrigerant oil from the removed compressor and measure its volume. Subtract the volume of drained oil from the original compressor oil capacity. The result is the amount of oil you should drain from the new compressor (through the suction fitting)
B.
Replace the O-rings with new ones at each fitting, and apply a thin coat of refrigerant oil before installing them. Be sure to use the right O-rings for R-134a to avoid leakage.
C.
To avoid contamination, do not return the oil to the container once dispensed, and never mix it with other refrigerant oils.
D.
Immediately after using the oil, replace the cap on the container and seal it to avoid moisture absorption.
Compressor Removal
1. If the compressor is marginally operable, run the engine at idle speed, and let the air conditioning work for a few minutes, then shut the engine off. ...

Compressor Inspection
1. Check the plated parts of the disc & hub assembly (A) for color changes, peeling or other damage. If there is damage, replace the clutch set. ...

See also:

Replacement
1. Disconnect the battery negative cable from the battery and then wait for at least 30 seconds. 2. Turn the steering wheel so that the fro ...

Head Lamp Aiming Instructions
The head lamps should be aimed with the proper beam-setting equipment, and in accordance with the equipment manufacturer's instructions.   ...

Delivery Pipe Installation
1. Install in the reverse order of removal. Delivery pipe installation bolt: 18.6 ~ 23.5 N.m (1.9 ~ 2.4 kgf.m, 13.7 ~ 17.4 lb-ft) ...