Kia Forte: Electric Oil Pump Removal - ISG (Idle Stop & Go) System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: Electric Oil Pump Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / ISG (Idle Stop & Go) System / Electric Oil Pump Removal

1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the Electric Oil Pump (EOP) connector (A).

3.
Remove the under cover after lifting the vehicle with lift. (Refer to Engine Mechanical System - "Engine Room Under Cover")
4.
Remove the Electric Oil Pump (B) after removing the bolts (A-4ea).

Tightening torque:
19.6 ~ 25.5 N.m (2.0 ~ 2.6 kgf.m, 14.4 ~ 18.8 lb-ft)

Electric Oil Pump Circuit Diagram
...

Electric Oil Pump Installation
1. Install in the reverse of removal. ...

See also:

Piston and Connecting Rod Reassembly
   • Thoroughly clean all parts to be assembled. • ...

Coolant Refilling And Bleeding
   Never remove the radiator cap when the engine is hot. Serious scalding could be caused by hot fluid under high pressure ...

Rear Seat Back Cover Component Location
(4Door, 2Door) 1. Rear seat back cover [LH] 2. Rear seat back cover [RH] (5Door) 1. Rear seat back assembly [LH] 2. Rear seat ...