Kia Forte: Electric Oil Pump Removal - ISG (Idle Stop & Go) System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: Electric Oil Pump Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / ISG (Idle Stop & Go) System / Electric Oil Pump Removal

1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the Electric Oil Pump (EOP) connector (A).

3.
Remove the under cover after lifting the vehicle with lift. (Refer to Engine Mechanical System - "Engine Room Under Cover")
4.
Remove the Electric Oil Pump (B) after removing the bolts (A-4ea).

Tightening torque:
19.6 ~ 25.5 N.m (2.0 ~ 2.6 kgf.m, 14.4 ~ 18.8 lb-ft)

Electric Oil Pump Circuit Diagram
...

Electric Oil Pump Installation
1. Install in the reverse of removal. ...

See also:

Starter Installation
1. Install in the reverse order of removal. Starter installation bolt: 49.0 ~ 63.7 N.m (5.0 ~ 6.5 kgf.m, 36.2 ~ 47.0 lb-ft) ...

Front Body
Front Body A * These dimensions indicated in this figure are actual-measurement dimensions. [ Unit : mm (inch) ] Front Body B * These dimensions indicated in th ...

Power Outside Mirror Switch Inspection
1. Disconnect the power door mirror switch module connector from front door trip panel. 2. Check for the continuity between termina ...