Kia Forte: Electric Oil Pump Removal - ISG (Idle Stop & Go) System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: Electric Oil Pump Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / ISG (Idle Stop & Go) System / Electric Oil Pump Removal

1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the Electric Oil Pump (EOP) connector (A).

3.
Remove the under cover after lifting the vehicle with lift. (Refer to Engine Mechanical System - "Engine Room Under Cover")
4.
Remove the Electric Oil Pump (B) after removing the bolts (A-4ea).

Tightening torque:
19.6 ~ 25.5 N.m (2.0 ~ 2.6 kgf.m, 14.4 ~ 18.8 lb-ft)

Electric Oil Pump Circuit Diagram
...

Electric Oil Pump Installation
1. Install in the reverse of removal. ...

See also:

Components
1. Intake camshaft 2. Exhaust camshaft 3. Intake CVVT assembly 4. Exhaust CVVT assembly 5. Timing chain 6. Timing chain tensioner arm 7. Timing chain tensioner 8. T ...

Installation
   • Do not spill brake fluid on the vehicle: it may damage the paint; if brake fluid does ...

Cooling Fan Description
[Air conditioning type] The cooling fan operates in 2 stages (HIGH/LOW). The engine control module (ECM) controls the cooling fan according to the coolant temperature, vehicle speed and A ...