Kia Forte: Electric Oil Pump Removal - ISG (Idle Stop & Go) System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: Electric Oil Pump Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / ISG (Idle Stop & Go) System / Electric Oil Pump Removal

1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the Electric Oil Pump (EOP) connector (A).

3.
Remove the under cover after lifting the vehicle with lift. (Refer to Engine Mechanical System - "Engine Room Under Cover")
4.
Remove the Electric Oil Pump (B) after removing the bolts (A-4ea).

Tightening torque:
19.6 ~ 25.5 N.m (2.0 ~ 2.6 kgf.m, 14.4 ~ 18.8 lb-ft)

Electric Oil Pump Circuit Diagram
...

Electric Oil Pump Installation
1. Install in the reverse of removal. ...

See also:

CVVT & Camshaft Description
Continuous Variable Valve Timing (CVVT) system advances or retards the valve timing of the intake and exhaust valve in accordance with the ECM control signal which is calculated by the engine ...

Troubleshooting Guide
Before Thinking The Product Has Malfunctioned 1. Errors which occur during the operation or installation of the device may be mistaken as a malfunction of the actual de ...

Rear Transverse Trim Component Location
(5Door) 1. Rear transverse trim ...