Kia Forte: Specification - Heating,Ventilation, Air Conditioning - Kia Forte TD 2014-2018 Service ManualKia Forte: Specification

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Heating,Ventilation, Air Conditioning / Specification

Air Conditioner
Item
Specification
Compressor
Type
6VS14 (MTC) / 6VSE14 (DFATC)
Oil type & Capacity
PAG(FD46XG) 110±10cc
Pulley type
6PK-TYPE
Displacement
142cc/rev
Condenser
Heat rejection
13,008-3% kcal/hr or 13,400-3% kcal/hr
Expansion valve
Type
Block type
Refrigerant
Type
R-134a
Capacity
530±25g

Blower Unit
Item
Specification
Fresh and recirculation
Operating method
Actuator
Blower
Type
Sirocco
Speed step
Auto + 8 speed (Automatic), 1~4speed (Manual)
Speed control
Power mosfet (Automatic), Resistor (Manual)
Air filter
Type
Particle filter

Heater and Evaporator Unit
Item
Specification
Heater
Type
Pin & Tube type
Heating capacity
4,800±5% kcal/hr
Mode operating method
Actuator
Temperature operating method
Actuator
Evaporator
Temperature control type
Evaporator temperature sensor
Cooling capacity
4600±% kcal/hr
A/C ON/OFF [°C(°F)]
ON : 2.1±0.5 (35.7±32.9), OFF: 0.6±0.5 (33.0±32.9)

Heating,Ventilation, Air Conditioning
...

Tightening Torque
Part tightened N.m Kgf.m lbf.ft Condenser - Discharge hose 7.8~11.7 0.8~1.2 5.7~8.6 Condenser - Liquid tube Comp ...

See also:

Rheostat Inspection
1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad side switch assembly (A). 3. ...

Components
1. Hands free call switch 2. Mic 3. Front left speaker 4. Front right speaker 5. Audio head unit (hands free control) ※ There is no hands free jack. ...

Adjustment
Glass Adjustment    • Check the glass run channel for damage or deterioration, and repl ...

Copyright © www.kifomanual.com 2014-2025