Kia Forte: Electric Oil Pump Removal - ISG (Idle Stop & Go) System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: Electric Oil Pump Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / ISG (Idle Stop & Go) System / Electric Oil Pump Removal

1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the Electric Oil Pump (EOP) connector (A).

3.
Remove the under cover after lifting the vehicle with lift. (Refer to Engine Mechanical System - "Engine Room Under Cover")
4.
Remove the Electric Oil Pump (B) after removing the bolts (A-4ea).

Tightening torque:
19.6 ~ 25.5 N.m (2.0 ~ 2.6 kgf.m, 14.4 ~ 18.8 lb-ft)

Electric Oil Pump Circuit Diagram
...

Electric Oil Pump Installation
1. Install in the reverse of removal. ...

See also:

Removal
   • Removal of the airbag must be performed according to the precautions/ procedures descr ...

AVN Head Unit Installation
1. Connect the AVN head unit connectors and cables. 2. Install the AVN head unit. 3. Install the airvent ducts ...

Specifications
Items Specification Hood Type Rear hinged, Front opening type, stay type Front Door Construction Front hinged, frame door constructi ...

Copyright © www.kifomanual.com 2014-2025