Kia Forte: Torque Converter Control Solenoid Valve (T/CON_VFS) Inspection
| 1. |
Turn ignition switch OFF.
|
| 2. |
Disconnect the Solenoid valve connector.
|
| 3. |
Measure resistance between sensor signal terminal and sensor ground
terminal.
|
| 4. |
Check that the resistance is within the specification.
(Refer to Torque Converter Control Solenoid Valve - "Specifications")
|
Torque Converter Control Solenoid Valve (T/CON_VFS) RemovalElectric Oil Pump Removal
1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the Electric Oil Pump (EOP) connector (A).
3.
...
CVVT (Continuously Variable Valve Timing) System Operation Principle
The CVVT has the mechanism rotating the rotor vane with hydraulic force
generated by the engine oil supplied to the advance or retard chamber in accordance
with the CVVT oil control valve con ...
Troubleshooting
Problem Symptoms Table
Use the table below to help you find the cause of the problem. The numbers
indicate the priority of the like cause of the problem. Check each part in order.
...