Kia Forte: 2. TCM Terminal Function
| Pin |
Description |
Pin |
Description |
| 1 |
- |
54 |
- |
| 2 |
Line pressure control solenoid valve (LINE_VFS) |
55 |
- |
| 3 |
Torque converter control solenoid valve (T/CON_VFS) |
56 |
- |
| 4 |
35R clutch control solenoid valve (35R/C_VFS) |
57 |
- |
| 5 |
- |
58 |
- |
| 6 |
- |
59 |
- |
| 7 |
Inhibitor switch signal "S1" |
60 |
- |
| 8 |
Inhibitor switch signal "S2" |
61 |
- |
| 9 |
Inhibitor switch signal "S3" |
62 |
- |
| 10 |
Inhibitor switch signal "S4" |
63 |
- |
| 11 |
- |
64 |
- |
| 12 |
- |
65 |
ON/OFF solenoid valve B(SS-B) |
| 13 |
- |
66 |
ON/OFF solenoid valve A(SS-A) |
| 14 |
- |
67 |
Battery (B+) |
| 15 |
- |
68 |
- |
| 16 |
- |
69 |
Oil temperature sensor (+) |
| 17 |
- |
70 |
- |
| 18 |
- |
71 |
- |
| 19 |
- |
72 |
- |
| 20 |
- |
73 |
Output speed sensor signal |
| 21 |
- |
74 |
- |
| 22 |
- |
75 |
- |
| 23 |
Underdrive brake control solenoid valve (UD/B_VFS) |
76 |
- |
| 24 |
26 brake control solenoid valve (26/B_VFS) |
77 |
- |
| 25 |
Overdrive clutch control solenoid valve (OD/C_VFS) |
78 |
- |
| 26 |
- |
79 |
- |
| 27 |
- |
80 |
- |
| 28 |
- |
81 |
- |
| 29 |
- |
82 |
- |
| 30 |
- |
83 |
- |
| 31 |
- |
84 |
- |
| 32 |
- |
85 |
- |
| 33 |
- |
86 |
Solenoid supply power 1 |
| 34 |
- |
87 |
Solenoid supply power 2 |
| 35 |
- |
88 |
Battery (B+) |
| 36 |
- |
89 |
- |
| 37 |
- |
90 |
Output speed sensor power |
| 38 |
- |
91 |
Input speed sensor power |
| 39 |
- |
92 |
- |
| 40 |
- |
93 |
- |
| 41 |
- |
94 |
Input speed sensor signal |
| 42 |
- |
95 |
- |
| 43 |
- |
96 |
- |
| 44 |
Ground (Power 1) |
97 |
- |
| 45 |
Ground (Power 2) |
98 |
- |
| 46 |
Shift lock solenoid |
99 |
- |
| 47 |
- |
100 |
- |
| 48 |
Oil temperature sensor (-) |
101 |
- |
| 49 |
- |
102 |
- |
| 50 |
- |
103 |
- |
| 51 |
- |
104 |
- |
| 52 |
- |
105 |
- |
| 53 |
- |
|
TCM Terminal Input/ Output SignalCanister Close Valve (CCV) Removal
1.
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
2.
Lift the vehicle.
3.
Dis ...
Description
Automatic transaxle system relies on various measurement data to determine
the current control status and extrapolate the necessary compensation values.
These values are used to control the a ...