Kia Forte: Underdrive Brake Control Solenoid Valve(UD/B_VFS) Inspection
| 1. |
Turn ignition switch OFF.
|
| 2. |
Disconnect the Solenoid valve connector.
|
| 3. |
Measure resistance between sensor signal terminal and sensor ground
terminal.
|
| 4. |
Check that the resistance is within the specification.
(Refer to Underdrive Brake Control Solenoid Valve - "Specifications")
|
Underdrive Brake Control Solenoid Valve(UD/B_VFS) RemovalIntake Actuator Description
The intake actuator is located at the blower unit. It regulates the intake
door by the signal from the control unit. Pressing the intake selection switch
will shift between recirculation and ...
ISG OFF Switch Description
The ISG OFF switch on the crash pad lower panel can be used to deactivate
the ISG function. ...
On-board Refueling Vapor Recovery (ORVR) valve Removal
1.
Turn the ignition switch OFF, and then remove battery (-) cable.
2.
Remove the fuel pump.