Kia Forte: CVVT Oil Control Valve (OCV) Removal - Engine Control System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: CVVT Oil Control Valve (OCV) Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / Engine Control System / CVVT Oil Control Valve (OCV) Removal

1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the CVVT oil control valve connector (A).
3.
Remove the installation bolt (B), and then remove the valve from the engine.
[Bank 1 / Intake]

[Bank 1 / Exhaust]

CVVT Oil Control Valve (OCV) Inspection
1. Turn the ignition switch OFF. 2. Disconnect the OCV connector. 3. Measure resistance between the OCV termina ...

CVVT Oil Control Valve (OCV) Installation
   • Install the component with the specified torques. • ...

See also:

Heater & A/C Control Unit (DATC) Component
Connector Pin Function Connector No. Description Connector No. Description A 1 Illumination (+) (Tail) A ...

Positive Crankcase Ventilation (PCV) Valve Inspection
1. Insert a thin stick (A) into the PCV valve (B) from the threaded side to check that the plunger movement.    ...

Components
1. Windshield glass 2. Windshield glass moulding ...

Copyright www.kifomanual.com 2014-2026