Kia Forte: CVVT Oil Control Valve (OCV) Removal
| 1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
| 2. |
Disconnect the CVVT oil control valve connector (A).
|
| 3. |
Remove the installation bolt (B), and then remove the valve from
the engine.
[Bank 1 / Intake]
[Bank 1 / Exhaust]
|
CVVT Oil Control Valve (OCV) Inspection
CVVT Oil Control Valve (OCV) InstallationInspection
Component Inspection
1.
Remove the clutch switch.
(Refer to Clutch Switch - "Removal")
2.
Push the clutch switch in the di ...
Cluster Ionizer Description
The cluster ionizer helps clean odor in the vehicle or from the air-conditioner
system.
When the ignition switch is ON, the inoizer runs a "CLEAN" mode and then
a "ION" ...
Specifications
Purge Control Solenoid Valve (PCSV)
▷ Specification
Item
Specification
Coil Resistance (Ω)
22.0 ~ 26.0 [20°C(68°F)]