1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the CVVT oil control valve connector (A).
3.
Remove the installation bolt (B), and then remove the valve from the engine.
[Bank 1 / Intake]

[Bank 1 / Exhaust]

CVVT Oil Control Valve (OCV) Inspection
1. Turn the ignition switch OFF. 2. Disconnect the OCV connector. 3. Measure resistance between the OCV termina ...

CVVT Oil Control Valve (OCV) Installation
   • Install the component with the specified torques. • ...