1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the mode control actuator connector.
|
3. |
Verify that the mode control actuator operates to the defog mode
when connecting 12V to the terminal 3 and grounding terminal 7.
Verify that the mode control actuator operates to the vent mode
when connecting in the reverse.
|
4. |
Connect the mode control actuator connector.
|
5. |
Turn the ignition switch ON.
|
6. |
Check the voltage between terminal 6 and 5.
Specification
It will feedback the current position of the actuator to the controls.
|
7. |
If the measured voltage is not within specification, substitute
with a known-good mode control actuator and check for proper operation.
|
8. |
Replace the mode control actuator if it is proved that there is
a problem with it.
|
SRS Control Module (SRSCM)
The primary purpose of the SRSCM (Supplemental Restraints System Control
Module) is to discriminate between an event that warrants restraint system deployment
and an event that does not. The ...
Floor Console Assembly Component Location
1. Floor console assembly
...
Components
...