Kia Forte: Starter Specification - Starting System - Engine Electrical System - Kia Forte TD 2014-2018 Service ManualKia Forte: Starter Specification

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Electrical System / Starting System / Starter Specification

Starter [Non-ISG type]
Item
Specification
Rated voltage
12 V, 1.2 kW
The number of pinion teeth
13
Performance
[No-load, 11 V]
Ampere
Max. 70 A
Speed
Min. 2,400 rpm

Starter [ISG type]
Item
Specification
Rated voltage
12 V, 1.4 kW
The number of pinion teeth
15
Performance
[No-load, 11.5 V]
Ampere
Max. 100 A
Speed
Min. 1,915 rpm

Starter Description
The starting system includes the battery, starter, solenoid switch, ignition switch, inhibitor switch (A/T), clutch pedal switch (M/T), ignition lock switch, connection wires and the battery ...

Starter Components
[NON-ISG Type] 1. Front bracket assembly 2. Magnet switch assembly 3. Lever 4. Reducer assembly 5. Lever stop 6. Gasket sheet 7. Yoke assembly 8. Armat ...

See also:

Parking Brake Cable Installation
1. Install the parking brake cable (A). Tightening torque : 8.8 ~ 14.7 N.m (0.9 ~ 1.4 kgf.m, 6.5 ~ 10.1 lb-ft) ...

Torque Converter Control Solenoid Valve (T/CON_VFS) Description
Torque converter control solenoid valve (T/CON_VFS) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the torque converter. ...

A/C Pressure Transducer Inspection
1. Measure the pressure of high pressure line by measuring voltage output between NO.1 and NO.2 terminals. 2. Inspect the voltage v ...