1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the CCV connector.
|
3. |
Measure resistance between the CCV terminal 1 and 2.
|
4. |
Check that the resistance is within the specification.
|
5. |
Disconnect the vapor hose connected with the canister from the
CCV.
|
6. |
Connect a vacuum pump to the nipple.
|
7. |
Ground the CCV control line and apply battery voltage to the CCV
power supply line.
|
8. |
Apply vacuum and check the valve operation.
|
Specifications
AVN Head Unit
Item
Specification
Power supply
DC 14.4V negative ground
Load Impedance
4ohm × 4
Tuning type
PLL SYNTH ...
Inspection
If any of the following conditions occur, WCS reset and accuracy check
should be performed.
•
The WCS ECU or any of the sensors is replaced.
•
...
SS-A Solenoid Valve(ON/OFF) Specifications
ON/OFF Solenoid Valve(SS-A, SS-B)
▷ Control type : Normal low type
Control pressure kpa (kgf/cm², psi)
490.33(5.0, 71.12)