Kia Forte: Temperature Control Actuator Inspection
| 1. |
Turn the ignition switch OFF.
|
| 2. |
Disconnect the temperature control actuator connector.
|
| 3. |
Verify that the temperature control actuator operates to the cool
position when connecting 12V to terminal 3 and grounding terminal 7.
Verify that the temperature control actuator operates to the warm
position when connected in reverse.
|
| 4. |
Connect the temperature control actuator connector.
|
| 5. |
Turn the ignition switch ON.
|
| 6. |
Check the voltage between terminal 6 and 7.
Specification
It will feedback the current position of the actuator to the controls.
|
| 7. |
If the measured voltage is not within specification, substitute
with a known-good temperature control actuator and check for proper
operation.
|
| 8. |
Replace the temperature control actuator if it is proved that
there is a problem with it.
|
Temperature Control Actuator Description
Temperature Control Actuator ReplacementPower Window Relay Inspection
Diagnosis With GDS
1.
It will be able to diagnose defects of power window with GDS quickly.
GDS can operates actuator forcefully, input/output value monitoring
and ...
Alternator Disassembly
1.
Remove the rear cover (A) after removing nuts (B).
2.
Remove the mounting bolts (A) and the regulator assembly (B).
...
Components
Components (1)
(4Door)
1. Front bumper cover
2. Front bumper upper weatherstrip
3. Front bumper side bracket [LH]
4. Front bumper side bracket [RH]
Co ...