Kia Forte: PTC Heater Description
| • |
Battery voltage : 13.0V or above
|
| • |
Engine : 900 rpm or above
|
| • |
Ambient temperature and coolant temperature
|
| Ambient Temperature |
Coolant Temperature |
PTC Operation |
| Below -20°C (-4°F) |
Below 75°C (167°F) |
ON |
| 10°C (50°F) |
Below 65°C (149°F) |
ON |
| 7°C (44.6°F) or above |
- |
OFF |
| - |
80°C (176°F) or above |
OFF |

Auto Defogging Actuator Replacement
PTC Heater InspectionExhaust Manifold Removal and Installation
1.
Remove the engine cover.
2.
Disconnect the battery negative terminal.
3.
Disconnect the front and rear oxyge ...
Removal
1.
Turn ignition switch OFF and disconnect the negative (-) battery
cable.
2.
Disconnect the vacuum pump connector (A).
...
Inspection
Component Inspection
1.
Remove the clutch switch.
(Refer to Clutch Switch - "Removal")
2.
Push the clutch switch in the di ...