Kia Forte: Heated Oxygen Sensor (HO2S) Removal
| [SULEV] |
| 1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
| 2. |
Disconnect the connector (A), and then remove the sensor (B).
[Bank 1 / Sensor 1]
[Bank 1 / Sensor 2]
|
| [LEV2] |
| 1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
| 2. |
Disconnect the connector (A), and then remove the sensor (B).
|
| 1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
| 2. |
Remove the console side cover (A).
|
| 3. |
Disconnect the connector (A), and then remove the sensor (B).
|
Heated Oxygen Sensor (HO2S) Inspection
Heated Oxygen Sensor (HO2S) InstallationExhaust Manifold Removal and Installation
1.
Remove the engine cover.
2.
Disconnect the battery negative terminal.
3.
Disconnect the front and rear oxyge ...
Oil Pump Unit (OPU) Inspection
OPU Problem Inspection Procedure
1.
TEST OPU GROUND CIRCUIT: Measure resistance between OPU and chassis
ground using the backside of OPU harness connector ...
Intake Manifold Removal and Installation
1.
Remove the engine cover.
2.
Disconnect the battery negative terminal.
3.
Disconnect the wiring connectors a ...