Kia Forte: 26 Brake Control Solenoid Valve(26/B_VFS) Circuit Diagram - Automatic Transaxle Control System - Automatic Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: 26 Brake Control Solenoid Valve(26/B_VFS) Circuit Diagram

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / 26 Brake Control Solenoid Valve(26/B_VFS) Circuit Diagram

26 Brake Control Solenoid Valve(26/B_VFS) Specifications
Direct control VFS[26/B] ▷ Control type : Normal low type Control Pressure kpa (kgf/cm², psi) 9.81 ~ 500.14 (0.1 ~ 5.1, 1.42 ~ 72.54) Current value(mA) ...

26 Brake Control Solenoid Valve(26/B_VFS) Inspection
1. Turn ignition switch OFF. 2. Disconnect the Solenoid valve connector. 3. Measure resistance between sensor ...

See also:

Components
1. Control shaft complete 2. Back-up lamp switch 3. Vehicle speed sensor 4. Transaxle housing 5. Transaxle case ...

Rear Seat Belt Retractor Component Location
(4Door, 2Door) 1. Rear seat belt retractor (5Door) 1. Rear seat belt retractor ...

Operation
1. General Function A. Auto-learn takes place only once per Ignition cycle. B. On successful compl ...