Kia Forte: Oil Cooler Inspection - Hydraulic System - Automatic Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: Oil Cooler Inspection

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Automatic Transaxle System / Hydraulic System / Oil Cooler Inspection

Radiator Cap Testing
1.
Remove the radiator cap, wet its seal with engine coolant, and then install it on a pressure tester.

2.
Apply a pressure of 93.16 ~ 122.58 kPa (0.95 ~ 1.25 kgf/cm², 13.51 ~ 17.78 psi).
3.
Check for a drop in pressure.
4.
If the pressure drops, replace the cap.
Radiator Leakage Test
1.
Wait until engine is cool, then carefully remove the radiator cap and fill the radiator with engine coolant, then install it on the pressure tester.
2.
Apply a pressure tester to the radiator and apply a pressure of 93.16 ~ 122.58kpa (0.95 ~ 1.25kg/cm², 13.51 ~ 17.78psi).

3.
Inspect for engine coolant leaks and a drop in pressure.
4.
Remove the tester and reinstall the radiator cap.
  
Check for engine oil in the coolant and/or coolant in the engine oil.
Oil Cooler Removal and Installation
1. Remove the cooling fan. (Refer to Cooling System - "Cooling Fan") 2. Remove the radiator upper hose (A). ...

Oil Pump Description
The oil pump is built-in as a single unit with the 26 Brake chamber. Rotation of the pump builds the hydraulic pressure needed for the lubrication of the various parts of the transaxle and op ...

See also:

Emergency starting
Connect cables in numerical order and disconnect in reverse order. Jump starting Jump starting can be dangerous if done incorrectly. Therefore, to avoid harm to yourself or damage to your vehic ...

Intake Manifold Removal and Installation
1. Remove the engine cover. 2. Disconnect the battery negative terminal. 3. Disconnect the wiring connectors a ...

Rear Bumper Cover Replacement
(4Door)    • Put on gloves to protect your hands. ...

Copyright © www.kifomanual.com 2014-2024