26 Brake Control Solenoid Valve(26/B_VFS) Specifications
Direct control VFS[26/B] ▷ Control type : Normal low type Control Pressure kpa (kgf/cm², psi) 9.81 ~ 500.14 (0.1 ~ 5.1, 1.42 ~ 72.54) Current value(mA) ...

26 Brake Control Solenoid Valve(26/B_VFS) Inspection
1. Turn ignition switch OFF. 2. Disconnect the Solenoid valve connector. 3. Measure resistance between sensor ...

See also:

Components
1. Front seat headrest 2. Front seat headrest guide 3. Front seat back cover 4. Front seat back warmer 5. Front seat back pad 6. Front seat back silener cloth 7. Front se ...

Fuel Tank Pressure Sensor (FTPS) Installation
   Х Install the component with the specified torques. Х ...

CVVT Oil Control Valve (OCV) Inspection
1. Turn the ignition switch OFF. 2. Disconnect the OCV connector. 3. Measure resistance between the OCV termina ...