Kia Forte: Blower Resistor Inspection - Blower - Heating,Ventilation, Air Conditioning - Kia Forte TD 2014-2018 Service ManualKia Forte: Blower Resistor Inspection

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Heating,Ventilation, Air Conditioning / Blower / Blower Resistor Inspection

1.
Measure terminal-to-terminal resistance of the blower resistor.
2.
If the measured resistance is not within specification, the blower resistor must be replaced. (After removing the resistor)

1. Middle low
2. Middle high
3. Low
4. High

Power Mosfet Replacement
1. Disconnect the negative (-) battery terminal. 2. Disconnect the power mosfet connector (A) and then remove the power mosfet (B) after lo ...

Blower Resistor Replacement
1. Disconnect the negative (-) battery terminal. 2. Disconnect the blower resistor connector (A) and then remove the blower resistor (B) af ...

See also:

Installation
1. Pre-tighten the bracket fixing bolt (A) in dash panel. 2. Install the brake booster and brake pedal member fixing nuts (A) secur ...

Tires/Wheels
   • Using tires and wheel other than the recommended sizes could cause unusual handling ...

Front Stabilizer Link Replacement
1. Loosen the wheel nuts slightly. Raise the vehicle, and make sure it is securely supported. 2. Remove the front wheel and tire (A ...