Kia Forte: Positive Crankcase Ventilation (PCV) Valve Inspection - Crankcase Emission Control System - Emission Control System - Kia Forte TD 2014-2018 Service ManualKia Forte: Positive Crankcase Ventilation (PCV) Valve Inspection

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Emission Control System / Crankcase Emission Control System / Positive Crankcase Ventilation (PCV) Valve Inspection

1.
Insert a thin stick (A) into the PCV valve (B) from the threaded side to check that the plunger movement.

  
If the plunger does not move (PCV valve is clogged), clean or replace the valve.
Positive Crankcase Ventilation (PCV) Valve Removal
1. Disconnect the vapor hose (A). 2. Remove the PCV valve (B). ...

Positive Crankcase Ventilation (PCV) Valve Installation
1. Installation is reverse of removal. PCV Valve installation: 1.96 ~ 2.94 N.m (0.2 ~ 0.3 kgf.m, 1.45 ~ 2.17 lb-ft) ...

See also:

Lubricants
Items Specified lubricant Quantity Transaxle gear oil SAE 75W/85, API GL-4 1.9 ~ 2.0 L (0.50 ~ 0.53 U.S.gal., 2.01 ~ 2.11 U.S. qt., 1.67 ~ 1.76 lmp ...

Removal
1. Disconnect the battery negative cable, and wait for at least thirty seconds before beginning work. 2. Remove the seat belt after pushin ...

SS-B Solenoid Valve(ON/OFF) Description
Shift Solenoid(SS) Valve-B is attached to the valve body and is an on/off solenoid valve that is used to change gears. Shift Solenoid(SS) Valve-B is installed at valve body. ...