Kia Forte: Purge Control Solenoid Valve (PCSV) Installation
•
|
Install the component with the specified torques.
|
•
|
Note that internal damage may occur when the component
is dropped. In this case, use it after inspecting.
|
|
•
|
Use care to keep foreign material out of the valve.
|
|
1. |
Install in the reverse order of removal.
Purge control solenoid valve
bracket installation bolt: 9.8 ~ 11.8 N.m (1.0
~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)
|
|
1.
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
2.
Disconnect the purge control solenoid valve connector (A) ...
Continuous Variable Valve Timing (CVVT) system advances or retards the
valve timing of the intake and exhaust valve in accordance with the ECM control
signal which is calculated by the engine ...