Kia Forte: CVVT Oil Control Valve (OCV) Removal - Engine Control System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: CVVT Oil Control Valve (OCV) Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / Engine Control System / CVVT Oil Control Valve (OCV) Removal

1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the CVVT oil control valve connector (A).
3.
Remove the installation bolt (B), and then remove the valve from the engine.
[Bank 1 / Intake]

[Bank 1 / Exhaust]

CVVT Oil Control Valve (OCV) Inspection
1. Turn the ignition switch OFF. 2. Disconnect the OCV connector. 3. Measure resistance between the OCV termina ...

CVVT Oil Control Valve (OCV) Installation
   • Install the component with the specified torques. • ...

See also:

High Mounted Stop Lamp Removal
[2 Door] 1. Disconnect the negative (-) battery terminal. 2. Remove the rear roof trim. (Refer to Body - "Roof Trim Assembly&qu ...

Installation
1. Install the multifunction switch. 2. Install the clock spring. 3. Install the steering column upper and lowe ...

Components
1. Steering column shaft 2. ECU 3. Motor 4. Steering gear box ...