Kia Forte: Line Pressure Control Solenoid Valve Specifications - Automatic Transaxle Control System - Automatic Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: Line Pressure Control Solenoid Valve Specifications

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Line Pressure Control Solenoid Valve Specifications

Direct control VFS[Line Pressure]
▷ Control type : Normal high type
Control Pressure kpa (kgf/cm², psi)
500.14 ~ 9.81 (5.1 ~ 0.1,72.54 ~ 1.42)
Current value(mA)
50 ~ 850
 Internal resistance(Ω)
5.1

Line Pressure Control Solenoid Valve Description
line pressure control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the line pressure. ...

Line Pressure Control Solenoid Valve Circuit Diagram
...

See also:

Front Strut Assembly Inspection
1. Check the strut bearing for wear and damage. 2. Check the spring upper and lower seat for damage and deterioration. 3. ...

Sealant
Items Specified sealant Control shaft assembly MS721-40 or MS721-38 ...

Variable Intake Solenoid (VIS) Valve Installation
   • Install the component with the specified torques. • ...