Kia Forte: Purge Control Solenoid Valve (PCSV) Description - Engine Control System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: Purge Control Solenoid Valve (PCSV) Description

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / Engine Control System / Purge Control Solenoid Valve (PCSV) Description

Purge Control Solenoid Valve (PCSV) is installed on the intake manifold and controls the evaporative purge between the canister and the intake manifold. It is a normally closed solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.

Injector Installation
   • Install the component with the specified torques. • ...

Purge Control Solenoid Valve (PCSV) Specification
Item Specification Coil Resistance (Ω) 22.0 ~ 26.0 [20°C(68°F)] ...

See also:

Body Panel Gaps
...

Specifications
Item Specifications Transaxle type A6GF1 Engine model Gasoline 1.8 MPI Torque converter type 3-element, 1-stage, 2-phase type ...

Camshaft Position Sensor (CMPS) Inspection
1. Check the signal waveform of the CMPS and CKPS using the GDS. Specification: Refer to “Wave Form” ...