1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the mode control actuator connector.
|
3. |
Verify that the mode control actuator operates to the defog mode
when connecting 12V to the terminal 3 and grounding terminal 7.
Verify that the mode control actuator operates to the vent mode
when connecting in the reverse.
|
4. |
Connect the mode control actuator connector.
|
5. |
Turn the ignition switch ON.
|
6. |
Check the voltage between terminal 6 and 5.
Specification
It will feedback the current position of the actuator to the controls.
|
7. |
If the measured voltage is not within specification, substitute
with a known-good mode control actuator and check for proper operation.
|
8. |
Replace the mode control actuator if it is proved that there is
a problem with it.
|
Specifications
Item
Specifications
Working voltage
DC 12V
Operating force
9.8 ± 2.9N
(1.0 ± 0.3kg, 7.2 ± 0.7lb)
Voltage drop
-0.4V
...
Input Speed Sensor Installation
1.
Installation is the reverse of removal.
After replacement or reinstallation procedure of ...