1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the auto defogging connector.
|
3. |
Verify that the auto defogging actuator operates to the open position
when connecting 12V to the terminal 3 and grounding terminal 7.
Verify that the auto defogging actuator operates to the close
position when connecting in the reverse.
|
4. |
Connect the auto defogging actuator connector.
|
5. |
Turn the ignition switch ON.
|
6. |
Check the voltage between terminals 6 and 5.
Specification
It will feedback the current position of the actuator to the controls.
|
7. |
If the measured voltage is not within specification, substitute
with a known-good auto defogging actuator and check for proper operation.
|
8. |
Replace the auto defogging actuator if it is proved that there
is a problem with it.
|
Fuel Tank Air Filter Installation
•
Install the component with the specified torques.
•
...
Replacement
Problems And Replacement Parts:
Problem
Part set
Scan tool required?
All keys have been lost
Blank key (4)
YES
Antenna coil unit does n ...
Inhibitor Switch Installation
1.
Check that the shift lever is placed in the "N" position
2.
Install the inhibitor switch (A).
...