1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the power mosfet connector (A) and then remove the power mosfet (B) after loosening the mounting screws.

3.
Install in the reverse order of removal.
Power Mosfet Inspection
1. Turn the ignition switch ON. 2. Manually operate the control switch and measure the voltage of the blower motor. 3. ...

Blower Resistor Inspection
1. Measure terminal-to-terminal resistance of the blower resistor. 2. If the measured resistance is not within specification, the blower re ...

See also:

Instrument Cluster Control
Adjusting Instrument Cluster Illumination The instrument panel illumination intensity can be adjusted by pressing the control switch with the headlight switch in any position when the ignition s ...

Description
Emissions Control System consists of three major systems. • The Crankcase Emission Control System prevents blow-by gas from releasing into the atmosphere. This system recy ...

Ignition Coil Installation
1. Install in the reverse order of removal. Ignition coil installation bolts: 9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 Ib-ft) ...