Kia Forte: Fuel Pump Removal - Fuel Delivery System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: Fuel Pump Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / Fuel Delivery System / Fuel Pump Removal

[LEV2]
1.
Release the residual pressure in fuel line (Refer to the Fuel Delivery System - Repair Procedures - "Release Residual Pressure in Fuel Line").
2.
Remove the rear seat.
(Refer to Body - “Rear Seat Assembly”)
3.
Remove the fuel pump service cover (A).

4.
Disconnect the fuel pump connector (A) and the fuel tank pressure sensor connector (B).
5.
Disconnect the fuel feed tube quick connector (C) and the vapor tube quick-connector (D).
6.
Remove the plate cover (E) after removing the mounting bolts.

7.
Remove the fuel pump from the fuel tank.

[SULEV]
1.
Release the residual pressure in fuel line (Refer to the Fuel Delivery System - Repair Procedures - "Release Residual Pressure in Fuel Line").
2.
Remove the rear seat.
(Refer to Body - “Rear Seat Assembly”)
3.
Remove the fuel pump service cover (A).

4.
Disconnect the fuel pump connector (A) and the fuel tank pressure sensor connector (B).
5.
Disconnect the fuel feed tube quick connector (C) and the vapor tube quick-connector (D).
6.
Remove the rubber cover (E).

7.
Unscrew the fuel pump plate cover with the special service tool (SST No.: 09310-2B200) and remove the fuel pump assembly.
8.
Remove the fuel pump from the fuel tank.

Fuel Pump Inspection
[Fuel pump] 1. Turn ignition switch OFF and disconnect the negative (-)battery cable. 2. Remove the fuel pump assembly. ...

Fuel Pump Installation
1. Install in the reverse order of removal.    Be careful of fuel pump direc ...

See also:

Hood switch Description
The hood switch is included as the influencing factors in the calculation of the ISG function. If the hood is open, the engine must not be started or stopped by the ISG function for safety re ...

Measurement Method
Projected Dimensions 1. These are the dimensions measured when the measurement points are projected into the reference plane, and are the reference dimensions ...

Inhibitor Switch Installation
1. Check that the shift lever is placed in the "N" position 2. Install the inhibitor switch (A). ...

Copyright www.kifomanual.com 2014-2026