Kia Forte: Line Pressure Control Solenoid Valve Specifications - Automatic Transaxle Control System - Automatic Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: Line Pressure Control Solenoid Valve Specifications

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Line Pressure Control Solenoid Valve Specifications

Direct control VFS[Line Pressure]
▷ Control type : Normal high type
Control Pressure kpa (kgf/cm², psi)
500.14 ~ 9.81 (5.1 ~ 0.1,72.54 ~ 1.42)
Current value(mA)
50 ~ 850
 Internal resistance(Ω)
5.1

Line Pressure Control Solenoid Valve Description
line pressure control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the line pressure. ...

Line Pressure Control Solenoid Valve Circuit Diagram
...

See also:

Oil Cooler Removal and Installation
1. Remove the cooling fan. (Refer to Cooling System - "Cooling Fan") 2. Remove the radiator upper hose (A). ...

Spark Plug Description
A spark plug is a device for delivering electric current from an ignition system to the combustion chamber of a spark-ignition engine to ignite the compressed fuel/air mixture therein by mean ...

Description
System Outline An optimal seat position set by a driver can be memorized in Power seat unit by IMS SW, which enables restoration of seat position set by the driver despite. P ...