Item |
Specification |
|
Rated voltage |
12 V, 1.2 kW |
|
The number of pinion teeth |
13 |
|
Performance [No-load, 11 V] |
Ampere |
Max. 70 A |
Speed |
Min. 2,400 rpm |
Item |
Specification |
|
Rated voltage |
12 V, 1.4 kW |
|
The number of pinion teeth |
15 |
|
Performance [No-load, 11.5 V] |
Ampere |
Max. 100 A |
Speed |
Min. 1,915 rpm |
Hazard Lamp Switch Removal
1.
Disconnect the negative (-) battery terminal.
2.
Remove the center fascia panel.
(Refer to Body - "Center Fascia Panel")
...
Power Outside Mirror Switch Removal
1.
Disconnect the negative(-) battery terminal.
2.
Remove the front door trim.
(Refer to Body - "Front Door Trim")
...
Transaxle Control Module (TCM) Inspection
Transaxle Control Module(TCM) Problem Inspection Procedure
1.
TEST TCM GROUND CIRCUIT: Measure resistance between TCM and chassis
ground using the backside of TCM harne ...