Kia Forte: AGM Battery Inspection - ISG (Idle Stop & Go) System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: AGM Battery Inspection

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / ISG (Idle Stop & Go) System / AGM Battery Inspection

Battery Diagnostic Flow

Vehicle parasitic current inspection
1.
Turn all the electric devices OFF, and then turn the ignition switch OFF.
2.
Close all doors except the engine hood, and then lock all doors.
(1)
Disconnect the hood switch connector.
(2)
Close the trunk lid.
(3)
Close the doors or remove the door switches.
3.
Wait a few minutes until the vehicle’s electrical systems go to sleep mode.
  
For an accurate measurement of a vehicle parasitic current, all electrical systems should go to sleep mode. (It takes at least one hour or at most one day.) However, an approximate vehicle parasitic current can be measured after 10~20 minutes.
4.
Connect an ammeter in series between the battery (-) terminal and the ground cable, and then disconnect the clamp from the battery (-) terminal slowly.
  
Be careful that the lead wires of an ammeter do not come off from the battery (-) terminal and the ground cable to prevent the battery from being reset. In case the battery is reset, connect the battery cable again, and then start the engine or turn the ignition switch ON for more than 10 sec. Repeat the procedure from No. 1.
To prevent the battery from being reset during the inspection,
1)
Connect a jump cable between the battery (-) terminal and the ground cable.
2)
Disconnect the ground cable from the battery (-) terminal.
3)
Connect an ammeter between the battery (-) terminal and the ground cable.
4)
After disconnecting the jump cable, read the current value of the ammeter.

5.
Read the current value of the ammeter.
A.
If the parasitic current is over the limit value, search for abnormal circuit by removing a fuse one by one and checking the parasitic current.
B.
Reconnect the suspected parasitic current draw circuit fuse only and search for suspected unit by removing a component connected with the circuit one by one until the parasitic draw drops below limit value.

Limit value (after 10~20 min.) : Below 50mA

AGM Battery Installation
1. Install in the reverse order of removal.    When installing the battery, ...

AGM Battery Cleaning
1. Make sure the ignition switch and all accessories are in the OFF position. 2. Disconnect the battery cables (negative first). ...

See also:

Front Wiper Motor Installation
1. Install the wiper motor. 2. Install the crank arm.    ...

Component Location
1. Fuel filler door ...

Battery Specifications
Battery [Non-ISG type] Item Specification Model type CMF60L-DIN Capacity [20HR / 5HR] (AH) 60 / 48 Cold Cranking Amperage (A) ...

Copyright © www.kifomanual.com 2014-2024