Kia Forte: Torque Converter Control Solenoid Valve (T/CON_VFS) Specifications - Automatic Transaxle Control System - Automatic Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: Torque Converter Control Solenoid Valve (T/CON_VFS) Specifications

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Torque Converter Control Solenoid Valve (T/CON_VFS) Specifications

Direct control VFS[T/CON]
▷ Control type : Normal low type
Control Pressure kpa (kgf/cm², psi)
9.81 ~ 500.14 (0.1 ~ 5.1,1.42 ~ 72.54)
Current value(mA)
50 ~ 850
 Internal resistance(Ω)
5.1

Torque Converter Control Solenoid Valve (T/CON_VFS) Description
Torque converter control solenoid valve (T/CON_VFS) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the torque converter. ...

Torque Converter Control Solenoid Valve (T/CON_VFS) Circuit Diagram
...

See also:

Starter Reassembly
1. Reassemble in the reverse order of disassembly. ...

Brake Booster
1. Brake booster 2. Master cylinder assembly 3. O-ring ...

Inhibitor Switch Installation
1. Check that the shift lever is placed in the "N" position 2. Install the inhibitor switch (A). ...