Adjustment
1.
After loosening the hinge (A) mounting bolt, adjust the hood (B)
by moving it up or down, or right or left.
2.
Adjust the hood height by ...
Compressor Oil Specification
1.
The R-134a system requires synthetic compressor oil (PAG) whereas
the R-12 system requires mineral compressor oil. The two oils must never
be mixed.
...
Basic Service Symbols
There are five primary symbols used to complement illustrations. These symbols
indicate the part to apply such materials during service.
Symbol
Meaning
...