Kia Forte: Heater & A/C Control Unit (Manual) Components

| Connector Pin Function |
| Connector |
No. |
Description |
Connector |
No. |
Description |
| A |
1 |
Ground |
B |
14 |
Intake actuator (Recirculation) |
| 2 |
Middle - High |
15 |
Sensor signal |
||
| 3 |
Middle - Low |
16 |
Ground |
||
| 4 |
High |
17 |
Illumination (+) (Tail) |
||
| 5 |
Common |
18 |
Sensor REF (+5V) |
||
| 6 |
Low |
19 |
Detent OUT (+) |
||
| B |
1 |
Battery (+) |
20 |
Max blower ON signal |
|
| 2 |
IGN 2 |
21 |
Evaporator temperature sensor (+) |
||
| 3 |
IGN 1 |
22 |
Ambient temperature sensor (+) |
||
| 4 |
HTD |
23 |
PTC relay (PTC only) |
||
| 5 |
Rear defog switch |
24 |
ECV (+) (ECV only) |
||
| 6 |
Mode actuator feedback |
25 |
ECV (-) - ground (ECV only) |
||
| 7 |
Temperature control actuator feedback |
26 |
- |
||
| 8 |
Intake actuator feedback |
27 |
C_CAN (High) |
||
| 9 |
Mode control actuator (Vent) |
28 |
C_CAN (Low) |
||
| 10 |
Mode control actuator (Defrost) |
29 |
- |
||
| 11 |
Temperature control actuator (Cool) |
30 |
Blower ON signal to common |
||
| 12 |
Temperature control actuator (Warm) |
31 |
Ground |
||
| 13 |
Intake actuator (Fresh) |
32 |
Illumination (-) (Rheostat) |
Controller
Heater & A/C Control Unit (Manual) ReplacementCluster Ionizer Inspection
1.
Press the MODE switch more then 4 times within 2 seconds while
pressing the OFF switch.
Display
Fail description
00 ...
Front Oil Seal Components
1. Front oil seal
...
Failure Diagnosis
1.
In principle, ESC and TCS controls are prohibited in case of ABS
failure.
2.
When ESC or TCS fails, only the failed system control is pr ...