Kia Forte: Electric Oil Pump Removal - ISG (Idle Stop & Go) System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: Electric Oil Pump Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / ISG (Idle Stop & Go) System / Electric Oil Pump Removal

1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the Electric Oil Pump (EOP) connector (A).

3.
Remove the under cover after lifting the vehicle with lift. (Refer to Engine Mechanical System - "Engine Room Under Cover")
4.
Remove the Electric Oil Pump (B) after removing the bolts (A-4ea).

Tightening torque:
19.6 ~ 25.5 N.m (2.0 ~ 2.6 kgf.m, 14.4 ~ 18.8 lb-ft)

Electric Oil Pump Circuit Diagram
...

Electric Oil Pump Installation
1. Install in the reverse of removal. ...

See also:

Components
1. Union bolt 2. Gasket 3. Tube joint 4. Clutch tube 5. Valve plate 6. Valve spring 7. Bleeder screw 8. Release cylinder 9. Return spring 10. Piston 11. Bo ...

Component Location
1. Driver power window switch 2. Door lock switch (Driver) 3. Passenger power window switch 4. Door lock switch (Passenger) 5. BCM (Body Control Module) 6. Front door loc ...

CVVT Oil Control Valve (OCV) Installation
   • Install the component with the specified torques. • ...