1. |
Disconnect the negative (-) battery cable.
|
2. |
Remove the air cleaner assembly and air duct.
(Refer to Engine Mechanical System - "Air cleaner")
|
3. |
Remove the under cover (A).
|
4. |
Replace new gasket and the plug after draining the automatic transaxle
fluid by removing the drain plug.
(Refer to Hydraulic System - "Fluid")
|
5. |
Remove the air breather hose (A).
|
6. |
Remove the valve body cover (B).
|
7. |
Disconnect the oil temperature sensor connector (A).
|
8. |
Remove the oil temperature sensor (A) after removing a bolt.
|
Troubleshooting
Symptom
Possible cause
Remedy
Tachometer does not operate
Cluster fuse (10A) blown
Check for short and replace fuse
CAN line faulty
...
Compressor Oil Specification
1.
The R-134a system requires synthetic compressor oil (PAG) whereas
the R-12 system requires mineral compressor oil. The two oils must never
be mixed.
...
Cooling Fan Specifications
Item
Specification
Fan type
PULLER
Fan speed control
Resistor (HI-LOW-OFF)
Air flow rate [㎥/h (yd³/h)]
1,700 (2,22 ...